The full article is currently under embargo for 12 months and will be made available on our website and PMC after this period. If you would like to access the article before it becomes publicly available, you can purchase it for personal use directly on our website. Alternatively, you may join SPUMS or EUBS to gain access to the entire issue.

Critical flicker fusion frequency measurement through a chamber porthole 

Jochen D Schipke1, Thomas Muth2, Anne-Kathrin Brebeck3, Sven Dreyer4

1 Research Group Experimental Surgery, University Hospital Düsseldorf, Germany
2 Institute of Occupational, Social, Environmental Medicine, Faculty of Medicine, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
3 Artemis Augenkliniken, Frankfurt am Main, Germany
4 Hyperbaric Oxygen Therapy, University Hospital Düsseldorf, Düsseldorf, Germany

Corresponding author: Professor Jochen Schipke, Research Group Experimental Surgery, University Hospital Düsseldorf, Germany
ORCID: 0000-0002-1747-5657
This email address is being protected from spambots. You need JavaScript enabled to view it.

Keywords
Diving research; Narcosis; Hyperbaric research

Abstract

(Schipke JD, Muth T, Brebeck AK, Dreyer S. Critical flicker fusion frequency measurement through a chamber porthole. Diving and Hyperbaric Medicine. 2025 December 20;55(4):419−422. doi: 10.28920/dhm55.4.419-422. PMID: 41364866.)
The critical flicker fusion frequency (cFFF) is a non-invasive measure of central nervous system function and cortical arousal, increasingly used in diving and hyperbaric medicine to assess the effects of breathing gases under pressure. This feasibility study aimed to evaluate whether cFFF can be reliably measured through the porthole of a hyperbaric chamber. Forty-five experienced male divers underwent cFFF testing at various pressures (101.3 kPa outside chamber, then 101.3, 608, 132, 101.3 kPa inside [1.0 bar outside then 1.0, 6.0, 1.3, 1.0 bar inside]) using a manually operated LED flicker-device while standing at a fixed distance from the chamber window. Results showed that cFFF values were higher inside the chamber at 101.3 kPa (1.0 bar) compared to outside (45.6 Hz vs. 40.2 Hz), decreased under hyperbaric conditions (608 kPa [6 bar], 43.5 Hz), and declined further during decompression (132 kPa [1.3 bar], 42.1 Hz; 101.3 kPa [1.0 bar], 43.5 Hz). These findings support previous observations of gas-induced central nervous system effects and highlight the sensitivity of cFFF to pressure-related neural changes. The successful external measurement protocol addresses challenges associated with observer narcosis and movement artifacts in underwater settings. While limited by the homogenous participant group and lack of confirmatory measures, this approach may still be a valuable tool for future research into the temporal dynamics of gas narcosis and cortical excitation.

Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

Diving and Hyperbaric Medicine

is indexed on

MEDLINE, Science Citation Index Expanded (SciSearch®) and Embase/Scopus and complies with the International Committee of Medical Journal Editors (ICMJE) Recommendation for the Conduct, Report, Editing and Publication of Scholarly Work in Medical Journals. Articles from 2017 are deposited in PubMed Central.